D1020S G.M. International s.r.l.
GM International

D1020S
SIL 2 Powered Isolating Driver Smart-HART® compatible DIN-Rail

The single and dual channel DIN Rail Isolating Driver, D1020S and D1020D, isolates and transfers a 4-20, 0-20 mA signal from a controller located in Safe Area to a load of up to 750 Ω in Hazardous Area. It has a high output capacity of 15 V at 20 mA combined with a low drop across its input terminals. The circuit allows bi-directional communication signals, for Smart I/P. In the 4-20 mA input range, a field open circuit reflects a high impedance to the control device output circuit.

FEATURES

  • SIL2 /SC3
  • Output to Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2.
  • High Density, two channels per unit.
  • 4-20 or 0-20 mA Input, Output Signal.
  • Wide Band Smart Communication, HART® compatible.
  • Field open circuit detection.
  • High Accuracy.
  • Three port isolation, Input/Output/Supply.
  • EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1
  • 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier.

STATUS

 
   PHASE-OUT
Next: SPARE-ONLY (2027-01-01)

Product lifecycle policy (EN)

ALTERNATIVE PRODUCT

CHANNELS

1

Request a free and personalized quotation!

Technical Data


Supply

Voltage 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, ripple within voltage limits ≤ 5 Vpp.
Current Consumption 50 mA with 20 mA output typical
Power Dissipation 1.0 W with 24 V supply voltage and 20 mA output typical
Max. power consumption at 30 V supply voltage and overload condition, 1.4 W

Input

Type 0/4 to 20 mA with ≤ 2.0 V voltage drop, reverse polarity protected.

Output

Type 0/4 to 20 mA, on max. 750 Ω load, current limited at ≈ 23 mA.
Response time 50 ms (10 to 90 % step change).
Output ripple ≤ 20 mVrms on 250 Ω communication load on 0.5 to 40 KHz band
Frequency response 0.5 to 40 KHz bidirectional within 3 dB (HART® and higher frequency protocols).

Performance

Type Ref. Conditions 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature.
Calibration accuracy ≤ ± 0.1 % of full scale.
Linearity error ≤ ± 0.05 % of full scale.
Supply voltage influence ≤ ± 0.05 % of full scale for a min to max supply change.
Load influence ≤ ± 0.05 % of full scale for a 0 to 100 % load resistance change.
Temperature influence ≤ ± 0.01 % on zero and span for a 1 °C change.

Isolation

Test Voltage I.S. Out/In 1.5 KV; I.S. Out/Supply 1.5 KV; I.S. Out/I.S. Out 500 V; In/Supply 500 V; In/In 500 V.

Environmental conditions

Operating temperature limits -20 to + 60 °C, relative humidity max 95 %.
Storage temperature limits – 45 to + 80 °C.

Safety description

Safety parameters Uo/Voc = 25.2 V, Io/Isc = 87 mA, Po/Po = 548 mW at terminals 14-15, 10-11. Um = 250 Vrms, -20 °C ≤ Ta ≤ 60 °C.

Mounting

Type EN/IEC60715 TH 35 DIN-Rail.
Weight about 120 g
Connection by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm2.
Location Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation.
Protection class IP 20.
Dimensions Width 22.5 mm, Depth 99 mm, Height 114.5 mm.

Data Sheet


Datasheet of D1020 ( EN )
D1000 Series Common Specifications and Dimensional Drawing ( EN )

Instruction Manual


Instruction Manual D1020 ( EN )
Instruction Manual D1000 Series ( EN | RU )
Ex safety instruction manual for D1000 series ( EN | IT )
INMETRO safety instruction manual for D1000 series ( PT )
UL Control Drawing D1020 ( EN )

Certifications


Type Description Area Number Issued by Issue Date
ATEX DEKRA ATEX D1000 Series English Certificate ( EN ) Europe DMT 01 ATEX E 042 X DEKRA 2022-04-25
ATEX IMQ Zone 2 Applications D1000 Series Certificate ( EN ) Europe IMQ 09 ATEX 013 X IMQ 2022-05-03
EMC D1000 EAC EMC Declaration of Conformity ( RU ) Eurasian Community ЕАЭС N RU Д-IT.НХ37.В.06311/20 EUROCERT 2020-08-13
Ex EAC Ex Certificate for D1000 Series ( RU ) Eurasian Community ЕАЭС RU С-IT.НА67.В.00113/20 TECHNOPROGRESS 2020-09-04
Ex UL-cUL D1010, D1020 Divisions and Zones ( EN ) North America 20130115-E222308C UL 2013-01-15
Ex FM No.3024643-3029921C Certificate ( EN ) North America 3024643-3029921C FM 2005-12-16
Ex INMETRO Certificate DNV 13.0108 X for D1000 series ( EN ) Brazil DNV 13.0108 X DNV 2022-12-10
FSM TUV IT 22 SIL 0093 Functional Safety Certificate ( EN ) International TUV IT 22 SIL 0093 TUV_SUD 2022-07-25
IECEx IMQ IECEx Zone 2 Applications D1000 Series Certificate ( EN ) International IECEx IMQ 13.0011X IMQ 2022-05-03
IECEx DEKRA IECEx for D1000 Series ( EN ) International IECEx BVS 07.0027X DEKRA 2022-05-30
Maritime KR Maritime Certificate D1000 Series ( EN ) International MIL20769-EL001 KR 2022-07-04
Metrological Metrological Certificate Russia for D1000 Series ( RU ) Russia 64283-11 ROSSTANDART 2021-03-10
SIL TUV C-IS-236198-03 SIL Certificate Summary ( EN ) International C-IS-236198-03 TUV_SUD 2022-10-14

Declarations of Conformity


EU Declaration of Conformity D1000 series ( EN | IT )
EU Declaration of Conformity for D1000 series (zone 2) ( EN | IT )
EU Declaration of Conformity for RoHS, ASBESTOS. ( EN )
Declaration of G3 compliance for D1000_PSD1000-PSD1001-PSD1001C-PSD1004-PSD1220-PSD1220-098 SERIES ( EN )

Dimensions


Image of D1020S-D1020D_size

Connections


Drawings


2d_drawing_D1000_dwg ( EN )
3d_drawing_D1000_dwg ( EN )
3d_drawing_D1000_stp ( EN )

RELATED PRODUCTS