This Termination Board with Enclosure (TBE) provides direct connection between the I/O Card of the system and D5000 / D6000 Series modules. The Intrinsically Safe protection and signal isolation between Safe and Hazardous Area, is provided by D5000 Series Associated Apparatus. The 24 Vdc Power Supply of the TBE is connected to two plug-in terminal blocks, for a redundant power supply.

FEATURES

  • Universal board interfaces
  • Connection to external GMI HART Mux 5700
  • 16 positions Termination Board for up to 32 channels
  • Lower cables installation and maintenance costs
  • Power supplies fault monitoring
  • Mounting hardware provided for single DIN Rail mounting kit

STATUS

 
   ACTIVE
Product lifecycle policy (EN)

CHANNELS

16 or 32

Request a free and personalized quotation!

Technical Data


General

Number of positions 16
Maximum number of channels 32

Supply

Voltage 24 Vdc nom (20 to 30 Vdc), reverse polarity protected, double terminal blocks for redundant power supply, with OR diodes to mix supply voltages.
Max allowed current consumption 1.5 A (as total supply).
Connection by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm².
Protection fuse 4 A time lag.

Fault detection

Type The on-board diagnostic monitors both power supplies integrity and the module cumulative fault. Any malfunction is reported by deactivating a solid-state relay and activating the corresponding LEDs. Alarm is issued if: 1) Power supply 1 or 2 < 17 Vdc or 2) Power supply 1 or 2 > 33 Vdc or 3) Module cumulative fault ON. Alarm is removed if: 1) 20 Vdc < Power supply 1 and 2 < 30 Vdc and 2) No module cumulative fault.
Connection by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm².
Output rating 100 mA 35 V (≤ 1 V voltage drop).

I/O Card Interface

Connection two SUB-D 37 poles male connectors (requiring female mating connectors).
Cable CABF034/xx, where "xx" indicates the length expressed in meters (5, 10, 20, 30 available).

HART Mux Interface

Connection 2 x 34-poles receptacle connector (require female mating connector).
Cable flat cable CABF032.

Environmental conditions

Operating temperature temperature limits –40 to +70 °C.
Max altitude 2000 m a.s.l.
Storage temperature temperature limits –45 to +80 °C.

Mounting

Type Hardware included for mounting on single DIN-rail 35 mm.
Weight about 1 kg, excluding modules (+ 50 g plastic clips or 380 g metal clips).
Location installation in Safe Area.
Dimensions Width 240 mm, Depth 180 mm, Height 154 mm.

Data Sheet


Datasheet of TBE-D5016-GMI-001 ( EN )
Schneider M580 Summary ( EN | RU | ES | DE | FR | CN | JA | IT | PT )

Instruction Manual


Instruction Manual Termination Boards GMI type ( EN )
Instruction Manual for installation of TBE-FIX-MT-xxx (valid for TBE-HRT & TBE-TRI & TBE-GMI) ( EN )
Instruction Manual for installation of TBE-FIX-PL-001 (valid for TBE-HRT & TBE-TRI & TBE-GMI) ( EN )

Declarations of Conformity


EU Declaration Termination Boards TB, TBE, TUE ( EN )

Dimensions


Image of TBE-D5016-GMI-001_size

Connections