D5037D

SIL 2 Switch/Proximity Detector Repeater Transistor Out

Description

The dual channel Switch/Proximity Detector Repeater D5037D module is a unit suitable for applications requiring SIL 2 level (according to IEC 61508:2010 Ed. 2) in safety related systems for high risk industries.
The unit can be configured for switch or proximity detector (EN60947-5-6, NAMUR), NO or NC and for NO or NC optocoupled open collector transistor output.
Each channel enables a Safe Area load to be controlled by a switch, or a proximity detector, located in Hazardous Area.
A fault detection circuit (DIP switch configurable) is available for proximity sensor and switch equipped with end of line resistors. In case of fault, when enabled it de-energizes the corresponding output transistor and turns the fault LED on; when disabled the corresponding output transistor repeats the input line open or closed status as configured.

Mounting on standard DIN-Rail, with or without Power Bus, or on customized Termination Boards, in Safe Area or in Zone 2.

Features

• Systematic capability SIL 3
• Input from Zone 0 (Zone 20), installation in Zone 2
• NO/NC switch/proximity Detector Input, NO/NC transistor driving mode.
• Field open and short circuit detection.
• Three port isolation, Input/Output/Supply.
• EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1, EN61326-3-1 for safety system.
• In-field programmability by DIP Switch.
• High Density, two channels per unit.
• Simplified installation using standard DIN-Rail and plug-in terminal blocks, with or without Power Bus, or customized Termination Boards.
• 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier.

Supply

18-30 Vdc

Channels

2 (1 Channel: D5037S )

SIL level

SIL 2
Image of D5037S_D5037D (WEB)

Download

    D5000 Series Common Specifications and Dimensional Drawing ( EN )
    Datasheet of D5037 ( EN | RU | FR | DE | ES | IT | CN | JA | PT )
    Instruction Manual D5000-D5200 Series ( EN )
    ATEX safety instruction manual for D5000 series ( EN | IT )
    INMETRO safety instruction manual for D5000 series ( PT )
    Instruction Manual D5037 ( EN )
    UL Control Drawing D5036, D5037 ( EN )
    Ex safety instruction manual for D5000 series ( RU )
    CCC Ex safety instruction manual for D5000 series ( EN | CN )
    ATEX > DEKRA > DEKRA ATEX D5000 Series English Certificate ( EN | DE )
    CCC_EX > GMI > D5000 CCC certificate for China ( EN )
    EAC_EMC > EAC > D5000/D6000 EAC EMC Declaration of Conformity ( RU )
    EAC_EX > CCVE > EAC Ex Certificate for D5000 Series (2nd half) ( RU )
    EMIRATES_EX > GMI > Emirates Certificate of Conformity D5000 ( EN )
    HAZARDOUS_LOCATION > UL > UL-cUL D5036, D5037 Divisions and Zones ( EN )
    IECEX > DEKRA > DEKRA IECEx for D5000 Series ( EN )
    INMETRO_EX > GMI > INMETRO Certificate DNV 13.0109 X for D5000 ( EN )
    MARITIME > KR > KR Maritime Certificate D5000 Series ( EN )
    MARITIME > DNV-GL > DNV Maritime Certificate TAA00001U0 for D5000 series for website ( EN )
    QMS_FS > TUV_SUD > TUV IT 22 SIL 0093 Functional Safety Certificate ( EN )
    SIL > TUV_SUD > TUV C-IS-236198-04 SIL Certificate Summary ( EN )
    EU Declaration of Conformity for RoHS, ASBESTOS. ( EN )
    EU Declaration of Conformity for D5000 barriers ( EN | IT )
    Declaration of Conformity G3 compliance ( EN )
    2D_drawing_D5000_dwg ( EN )
    3D_drawing_D5000_dwg ( EN )
    3D_drawing_D5000_stp ( EN )
    JDFT04912mm DIN Rail Connector
    MCHP196Power Bus Terminal Block Cover and Fix
    MORT017Plug-in Terminal Block male, Horizontal Output, for Bus Power
    MORT022Plug-in Terminal Block female, Horizontal Output, for Bus Power

Status

AVAILABLE
> Product lifecycle policy ( EN )

 

Request a quotation

« Previous: D5036S
D5037D
Next: D5037S »