X1-TB-16-TRI-01 G.M. International s.r.l.
GM International

X1-TB-16-TRI-01
I.S. SIL3 16-pos X1-Series Term. Board for Tricon CX UIO 3902(A)X and AO 3809(A)X Card

This Termination Board (X1-TB) provides direct connection between the I/O Card of the system and X1-Series modules. The Intrinsically Safe protection and signal isolation between Safe and Hazardous Area is provided by X1-Series Associated Apparatus (X1-IS). The 24 Vdc Power Supply of the X1-TB is connected to two plug-in terminal blocks, for a redundant power supply. The board can host a gateway belonging to the X1-GW series for configuration and monitoring features.

FEATURES

  • SIL 3 / SC 3
  • Input from Zone 0 / Division 1
  • Installation in Zone 2 / Division 2
  • Tricon CX UIO & AO Card board interface
  • 16 positions universal board interface for up to 16 channels
  • Lower cables installation and maintenance costs
  • Single loop disconnection to ease maintenance operations
  • Possibility of hosting X1-GW gateway for configuration & monitor
  • Three port isolation, Input/Output/Supply

STATUS

 
   ACTIVE
Product lifecycle policy (EN)

CHANNELS

16

Request a free and personalized quotation!

Technical Data


General

Number of positions/channels 16
Power Dissipation 0.24 W @ 24 Vdc with both supplies and without modules, typical.

Supply

Voltage 24 Vdc nom (20 to 30 Vdc), reverse polarity protected, double terminal blocks for redundant power supply, with OR diodes to mix voltages.
Current Consumption 10 mA @ 24 Vdc with both supplies and without modules, typical.
Max current consumption 1.5 A (as total supply), 3.15 A time-lag fuse protected.
Connection by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm².

Field Interface

Connection by polarized plug-in disconnect 8-position screw or push-in spring terminal blocks to accommodate terminations up to 2.5 mm².

System interface

Type The system interface sinks current.
Connection one SUB-D 50 poles male connector (requiring female mating connector).
Cable system cable 4X00227-5xx with AO Card 3809X, 4X00224-3xx with UIO Card 3902X.
Max current 500 mA per channel.

Earth Interface

Connection screw terminal block for conductors up to 2 mm².

Isolation

Test Voltage Field/System 2.5 kV; Field/Supply 2.5 kV; System/Supply 500 V; Earth/System 500 V; Earth/Field 500 V; Earth/Supply 500 V.

Environmental conditions

Operating temperature temperature limits –40 to +70 °C.
Max altitude 2000 m a.s.l.
Storage temperature temperature limits –45 to +80 °C.

Safety description

Equipment Associated apparatus and non-sparking electrical equipment.
Safety parameters Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.

Mounting

Type Hardware included for mounting on single DIN-rail 35 mm.
Weight about 1 kg, escluding modules.
Location Safe Area or Zone 2 or Division 2.
Dimensions Width 243 mm, Depth 143 mm, Height 155 mm.

Data Sheet


Datasheet of X1-Series Tricon CX Summary ( EN )

Instruction Manual


Instruction Manual of X1-TB-16-TRI-01 ( EN )
FM Control Drawing of X1-TB-16-TRI-01 ( EN )
Safety Information of X1-TB-16-TRI-01 ( EN )

Certifications


Type Description Area Number Issued by Issue Date
ATEX FM ATEX I.S. X1 Series English Certificate ( EN ) Europe FM23ATEX0038X FM 2025-01-13
Ex FM US X1 Series Divisions and Zones English Certificate ( EN ) North America FM23US0073X FM 2025-01-09
Ex FM Canada X1 Series Divisions and Zones English Certificate ( EN ) North America FM23CA0055X FM 2025-01-09
IECEx FM IECEx X1 Series English Certificate ( EN ) International IECEx FMG 23.0018X FM 2025-01-09
UKEx FM UKEx I.S. X1 Series English Certificate ( EN ) United Kingdom FM23UKEX0039X FM 2025-01-15

Dimensions


Image of X1-TB-16-TRI-01_size

Connections