X1-NIS-AI-01-S G.M. International s.r.l.
GM International

X1-NIS-AI-01-S
SIL3 2-Wire Passive/Active HART® Tx Current Repeater

The Current Repeater Power Supply X1-NIS-AI-01 module is a high integrity analog input interface suitable for applications requiring SIL 3 level in safety related systems for high risk industries. It provides an isolated supply for energizing conventional two-wire passive 4-20 mA transmitters, while repeating the current to the system card. Two-wire active transmitters are also supported. The circuit allows bi-directional HART® communication for both passive and active devices. The module always sinks current and the Termination Board extends its use to source loops. An out-of-range current fault according to IEC 60947-5-6 NAMUR NE 43 standard is available with limits configurable through the optional Gateway. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction lever mechanism. This product requires a dedicated Termination Board.

FEATURES

  • SIL 3 / SC 3
  • Installation in Zone 2 / Division 2
  • Loop disconnection to ease maintenance operations
  • 4-20 mA 2-wire Active-Passive Input
  • HART® compatible
  • Out-of-range fault according to IEC 60947-5-6 NAMUR NE 43
  • Input and Output short circuit proof
  • High Accuracy
  • Three port isolation, Input/Output/Supply

STATUS

 
   ACTIVE
Product lifecycle policy (EN)

CHANNELS

1

Request a free and personalized quotation!

Technical Data


General

Power Dissipation 0.55 W (passive Tx), 1.05 W (active Tx) @ 24 Vdc with 20 mA, 24 Vdc + 250 Ω output, typical.

System Supply

Voltage 24 Vdc nom (18 to 30 Vdc).
Current Consumption 23 mA @ 24 Vdc with 20 mA, typical.

System Out

Type Current 4 to 20 mA. The module always sinks current and the Termination Board extends its use to source loops.
Response time ≤ 20 ms (4 to 20 mA or 20 to 4 mA).
Current limitation 26 mA typical.
Maximum load 600 Ω.
Maximum voltage 30 V.
Minimum voltage 15 V (including series resistance voltage drop).

Field In

Type Current 4 to 20 mA, passive or active Tx.
Passive Tx line voltage 20 V minimum @ 20 mA.
Active Tx voltage drop 6.5 V maximum @ 20 mA.
Current limitation 26 mA typical.

Fault

Type An out-of-range fault with configurable limits is available on the common fault line.

Performance

Ref. Conditions 24 V supply, 24 V + 250 Ω output, 23 ± 1 °C ambient temperature.
Linearity accuracy ≤ ± 20 µA.
Calibration accuracy ≤ ± 20 µA.
Temp. influence ≤ ± 2 µA/°C.

Isolation

Test Voltage Field In/System Out 2.5 kV; Field In/System Supply 2.5 kV; System Out/System Supply 500 V.

Environmental conditions

Operating temperature temperature limits –40 to +70 °C.
Storage temperature temperature limits –45 to +80 °C.

Mounting

Type On custom Termination Board.
Weight about 55 g.
Dimensions Width 10 mm, Depth 80 mm, Height 120 mm.

Data Sheet


Datasheet of X1-NIS-AI-01 ( EN )

Instruction Manual


Instruction Manual of X1-NIS-AI-01 ( EN )
Safety Manual of X1-NIS-AI-01-S ( EN )
Safety Information of X1-NIS-AI-01-S ( EN )

Certifications


Type Description Area Number Issued by Issue Date
ATEX FM ATEX zone 2 X1 Series English Certificate ( EN ) Europe FM23ATEX0039X FM 2025-01-13
Ex FM US X1 Series Divisions and Zones English Certificate ( EN ) North America FM23US0073X FM 2025-01-09
Ex FM Canada X1 Series Divisions and Zones English Certificate ( EN ) North America FM23CA0055X FM 2025-01-09
FSM TUV IT 22 SIL 0093 Functional Safety Certificate ( EN ) International TUV IT 22 SIL 0093 TUV_SUD 2022-07-25
IECEx FM IECEx X1 Series English Certificate ( EN ) International IECEx FMG 23.0018X FM 2025-01-09
SIL TUV IT 25 SIL 0528 A SIL Certificate Summary ( EN ) International TUV IT 25 SIL 0528 A TUV_SUD 2025-01-29
UKEx FM UKEx zone 2 X1 Series English Certificate ( EN ) United Kingdom FM23UKEX0040X FM 2025-01-15

Declarations of Conformity


EU Declaration of Conformity of X1-NIS-AI-01 ( EN | IT )
UK Declaration of Conformity of X1-NIS-AI-01 ( EN )

Dimensions


Image of X_size

Connections