SIL3 24/220-Vdc/Vac Voltage Transistor-Out Detector

The Vdc/Vac Voltage Detector X1-NIS-RLI-01 module is a unit suitable for applications requiring SIL 3 level in safety related systems for high risk industries. The module is able to reflect the presence of a 24 to 220 Vac/Vdc nominal input signal to the output by closing an optically coupled open-collector transistor, which guarantees reinforced insulation to the field. The input voltage presence is also indicated by a yellow LED on the front panel. DC signals have a separated interface for a faster response time. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.

FEATURES

  • SIL 3 / SC 3
  • Installation in Zone 2 / Division 2
  • Loop disconnection to ease maintenance operations
  • Separate interface for DC signals for faster response time
  • Reinforced insulation, Field to System
  • Three port isolation, Input/Output/Supply

STATUS

 
   ACTIVE
Product lifecycle policy (EN)

CHANNELS

1

Request a free and personalized quotation!

Technical Data


General

Power Dissipation 0.45 W, @ 24 Vdc System Supply, 220 Vac input voltage and 10 mA output current, typical.

System Supply

Voltage 24 Vdc nom (18 to 30 Vdc).
Current Consumption 15 mA, @ 24 Vdc with closed output contact, typical.

System Out

Type Voltage free SPST optocoupled open-collector transistor.
Max voltage 35 Vdc.
Max current 50 mA.
Max voltage drop 1.5 V @ 50 mA.
Leakage current ≤ 50 μA @ 35 Vdc.
Response time ≤ 1 ms (DC input), ≤ 100 ms (AC input).

Field In (AC Source)

Type AC Voltage signal.
Voltage range 0 to 250 Vrms.
Switching thresholds OFF ≤ 15 Vrms, ON ≥ 20 Vrms.
Input impedance 500 kΩ, typical.

Field In (DC Source)

Type DC Voltage signal.
Voltage range 0 to 250 V.
Switching thresholds OFF ≤ 14 V, ON ≥ 17 V.
Input impedance 400 kΩ, typical.

Isolation

Test Voltage Field In/System Out 2.5 kV; Field In/System Supply 2.5 kV; System Out/System Supply 500 V.

Environmental conditions

Operating temperature temperature limits –40 to +70 °C.
Storage temperature temperature limits –45 to +80 °C.

Mounting

Type On custom Termination Board.
Weight about 50 g.
Dimensions Width 10 mm, Depth 80 mm, Height 120 mm.

Data Sheet


Datasheet of X1-NIS-RLI-01 ( EN )

Instruction Manual


Safety Information of X1-NIS-RLI-01-S ( EN )
Instruction Manual of X1-NIS-RLI-01 ( EN )
Safety Manual of X1-NIS-RLI-01-S ( EN )

Certifications


Type Description Area Number Issued by Issue Date
ATEX FM ATEX zone 2 X1 Series English Certificate ( EN ) Europe FM23ATEX0039X FM 2025-01-13
Ex FM US X1 Series Divisions and Zones English Certificate ( EN ) North America FM23US0073X FM 2025-01-09
Ex FM Canada X1 Series Divisions and Zones English Certificate ( EN ) North America FM23CA0055X FM 2025-01-09
FSM TUV IT 22 SIL 0093 Functional Safety Certificate ( EN ) International TUV IT 22 SIL 0093 TUV_SUD 2022-07-25
IECEx FM IECEx X1 Series English Certificate ( EN ) International IECEx FMG 23.0018X FM 2025-01-09
SIL TUV IT 25 SIL 0530 A SIL Certificate Summary ( EN ) International TUV IT 25 SIL 0530 A TUV_SUD 2025-01-29
UKEx FM UKEx zone 2 X1 Series English Certificate ( EN ) United Kingdom FM23UKEX0040X FM 2025-01-15

Declarations of Conformity


EU Declaration of Conformity of X1-NIS-RLI-01 ( EN | IT )
UK Declaration of Conformity of X1-NIS-RLI-01 ( EN )

Dimensions


Image of X_size

Connections